Forum Post: RE: bq20z95 PRES contact with 7V cause it report abnormal higher error voltage

$
0
0

Simon,

The absolute maximum voltage rating for the PRES/ input is 2.8V to 2.9V. The internal ESD structure will get damaged, if the input is connected to PACK+ voltage levels.

Regards
Tom