Forum Post: RE: Bad HF Dynamic Impedance values leading to cell balancing problems and DEAD PACK

$
0
0

Hi Tom,

Yes we are working together, but there are some points i want answered.

  • What I don't understand is why are OCV values still approximated/calculated even though the cell has been in a relaxed state for many hours? - Noise susceptible design...(I know normal impedance is low but still.)
  • Will keeping the 'Wired bit' low prevent updates of the HF values?
  • [quote user="ThomasCosby"]that the PL116 was setup to balance on OCV and it got into a state where the cells became significantly imbalanced.[/quote] - Did an extreme imbalance occur OR was there an EUV flag raised due to charge being thrown around for a long time? There are two possible conditions here. I think the latter.

Regards,

Bruce