Forum Post: RE: TPS40192: Undershooting generating to Vo.

$
0
0

Hi Na

I convey a result of the wave pattern observation by TPS40192EVM525.
As a result, I was able to acquire similar waveform.

Condition:
a. There is no fixed number change in TPS40192EVM525.
b. I connect electrolysis capacitor 470μF and two MLCC 22μF to the Vin side.
c. I do not connect load to the Vout side.
d. It supplies 12V to the Vin side. 

CH1: Vin(TP1)   CH2: Vout(TP15)   CH3: LDRV(TP10)   CH4: COMP(TP6)

The mean voltage of Vout is around 0.2V outbreak at the time of phenomenon outbreak.
The undershoot is around 0.9V outbreak.
In addition, the COMP signals identify a similar wave pattern, too.

Please tell me the logic of the outbreak.

Thanks,
 Masami