Forum Post: BQ2060 - Wrong Remaining Capacitance counting while charging but OK while discharging

$
0
0

Hello all,

I'm working with a battery pack 4 cells lithium in series and total capacity 3000mAh.

Pack is controlled by BQ2060 IC and the problem I see is the Remaining Capacity estimation while charging results in a wrong value. 

When the battery is charged it reports around one third (around 1000mAh) of its total charge.

At this point, I change manually this remaining capacity to 3000mAh and then I start discharging the battery. While discharging, the Remaining Capacity counting looks working well because in parallel I'm measuring with oscilloscope current/time and both values, oscilloscope measurement and BQ2060 RM matches.

  Finally, when battery becomes discharged RM says almost zero.

A wrong VFC calibration could explain this behaviour, RM wrong while charging and OK while discharging?

Thanks in advance for your support,

Best Regards,

Manel.