Forum Post: TPS23753 Oring Power OFF

$
0
0

Hi, 

I was reading the application report SLVA306A about the advanced adapter Oring solution using the TPS23753 and I can't seem to find an option where the gate drive continue switching while the adapter is plug/unplug. It seem there is always a time period, the PSE turn ON and the ADP shut OFF, where the gate drive stop.

It seem possible reducing that time OFF by using DVDD, a diode between the VDD and VDD1 as option 2 describe but not keeping the gate running. 

Is there a possibility to load with 10mA the input so the MPS is maintain, use an external supply and when that external supply is removed, the gate drive doesn't stop.

Thanks

Frederic Jutras