Forum Post: RE: Full charge capacity for bq34z100

$
0
0

Michael

The DataRAM screen shot indicates that you do not have Impedance Track enabled, so gauging will not work properly. You will need to issue an IT Enable (21) command by typing a 21 into the Control field and pressing <enter>. You should see the QEN flag turn red. This will force an OCV simulation that should update the capacity estimates.

Regards

Tom